B4200 Selectable Programmable Digital MultiMeter

Inquire now

B4200 Selectable Programmable Digital MultiMeter

Click to enlarge image

 Model Number B4200
 Brand Name Seintek

Catalog

Users Manual Software

Features

  • Programmable record (MAX / MIN): records and displays the MAX and MIN values of the input freq.

  • Programmable Relative (REF / ERR): displays reference frequency and the deviation of the measured frequency from the reference frequency as a % error.

  • Programmable Compare (GO-NOGO): the LCD will display PASS if the input frequency is with in the HI/LO limits, LO if the frequency is lower than the LO limit and HI if the frequency is higher than the HI limit.

  • Measurement: DCV, ACV, OHM, BEEP, DIODE, FREQ, DC μA/mA, DCA, AC μA/mA and ACA

  • Resolution : Selectable 3-1/2 to 5-1/2 Digit resolution (Fast, Middle, Slow mode)

  • Accuracy: 0.001ohm, Error : 0.05%

  • True RMS, AC

  • Range: full auto range

  • Trend Plot: the REF is the centerline value on the trend graph, H/Div is the X axis (time) and V/DIV is the Y axis (amplitude).

  • Setup: setting and functions may be selected and stored in memory from the front panel.
    Eight setups may be stored in memory.

  • Equipment: displays information about your instrument including the Model number, serial number, calibration date, GP-IB address and Firmware revision.

  • Remote control: function and ranges may be controlled from a PC via the RS232 or the optional GP-IB interface.

  • Display: 128 by 64 pixel super twisted LCD display

  • Power source: may be used with any line voltages from 85V to 270Vac (±10%, 48 to 66Hz) without any internal changes.

Record Relative Compare
Trend Plot Setup Equipment

▣ Specification

- DC V

Range Resolution Accuracy Impedance Max. Input Voltage
Slow Medium Fast
2 V 0.00001V0.0001V 0.001V ±(0.05%+3) 10 ±1,000 V
20 V 0.0001V0.001V 0.01V
200 V 0.001V0.01V 0.1V
1000 V 0.01V0.1V 1V ±(0.1%+5)

- AC V - Crest Factor is 3 : 1.

Range Resolution Accuracy Impedance Max. Input Voltage
Slow Medium Fast
2 V
0.0001V 0.0001V0.001V

±(0.5%+5)

10 MΩ ±1,000 V
20 V 0.001V 0.001V0.01V
200 V 0.01V 0.01V0.1V
1000 V 0.1V 0.1V1V

±(0.75%+5)

- OHM

Range Resolution Accuracy Max. Input Voltage
Slow Medium Fast
200 Ω 0.001 Ω0.01 Ω 0.1 Ω ±(0.2%+5) ±250 V
2 kΩ 0.00001 kΩ0.0001 kΩ 0.001 kΩ ±(0.05%+5)
20 kΩ 0.0001 kΩ0.001 kΩ 0.01 kΩ
200 kΩ 0.001 kΩ0.01 kΩ 0.1 kΩ
2 MΩ 0.00001 MΩ0.0001 MΩ 0.001 MΩ
20 MΩ 0.0001 MΩ0.001 MΩ 0.01 MΩ ±(0.2%+5)

- BEEP: 100Ω or less

- Diode

Range Resolution Max Test Current Max. Input Voltage
Slow Medium Fast

2 V

0.00001 V

0.0001 V 0.001 V About 1mA ±250 V

- Frequency

Range Resolution Accuracy Max. Input Voltage
Slow Medium Fast
200 Hz 0.001 Hz 0.001 Hz 0.001 Hz ±(0.05%+2) ±250 V
2 kHz 0.00001 kHz 0.00001 kHz 0.0001 kHz
20 kHz 0.0001 kHz 0.0001 kHz 0.0001 kHz
200 kHz 0.001 kHz 0.001 kHz 0.001 kHz
2 MHz 0.00001 MHz 0.00001 MHz 0.00001 MHz

- DC μA

Range Resolution Accuracy Max. Burden Overload Protection
Slow Medium Fast
200 μA 0.001 μA 0.01 μA 0.1 μA ±(0.1%+5) ≤ 200 mV 0.5A/250V
Fused

- DC mA

Range Resolution Accuracy Max. Burden Overload Protection
Slow Medium Fast
200 mA 0.001 mA 0.01 mA 0.1 mA ±(0.1%+5) ≤ 200 mV 0.5A/250V
Fused

- DC A - (Max. Input Current: 10 A)

Range Resolution Accuracy Max. Burden Overload Protection
Slow Medium Fast
10 A 0.0001 A 0.001 A 0.01 A ±(0.1%+5) ≤ 200 mV 10A/250V
Fused

- AC μA

Range Resolution Accuracy Max. Burden Overload Protection
Slow Medium Fast
200 μA 0.01 μA 0.01 μA 0.1 μA ±(0.5%+5) ≤ 200 mV 0.5A/250V
Fused

- AC mA

Range Resolution Accuracy Max. Burden Overload Protection
Slow Medium Fast
200 mA 0.01 mA 0.01 mA 0.1 mA ±(0.5%+5) ≤ 200 mV 0.5A/250V
Fused

- AC A - Crest Factor is 3 : 1. (Max. Input Current: 10 A)

Range Resolution Accuracy Max. Burden Overload Protection
Slow Medium Fast
10A 0.001 A 0.001 A 0.01 A ±(0.5%+5) ≤ 200 mV 10A/250V
Fused

- General

Power requirement 85V~270Vac (±10%, 48 ~ 66 Hz)
Dimension 235 (W) x 296 (D) x 85(H) (mm)
Weight Approx. 1.5 kg

- Packing Details

Packing Q`ty Size(mm) N.W.(Kg) G.W(Kg)
Inner 1 265(L) x 375(W) x 115(H) - 2.2
Carton 4 550(L) x 405(W) x 270(H) 8.8 10

ACCESSORY

- Standard

1. User Manual
2. Test Probe
3. Cord
4. Spare fuse
5. RS232 Cable (9Pin to 9Pin)
6. RS232 Program Software Diskette

- Option

1. GP-IB (IEEE-488.2) Interface (Installed)